The NEW Waltron 9096 Degas Cation Conductivity Analyzer delivers accurate measurement of specific, cation, and degassed cation conductivity with unprecedented degassing efficiency of over 94% in under 90 seconds.
During the start up of a thermal power plant, the purity of the generated steam determines whether it can be sent to the steam turbine or if it has to be bypassed to the condenser. Traditionally “Cation Conductivity” instruments are used to analyze steam quality, but in addition to measuring harmful ionic compounds (e.g. Chlorides), they also include CO2, which is not significantly harmful to the steam turbine.
The Waltron 9096 Degas Cation Conductivity Analyzer is based on a patent-pending “Dynamic System”, meaning it does not use a reboiler or require any supplemental inert gases.
This instrument uses ambient air forced against the flow of the water sample to achieve its high degassing efficiency, resulting in significantly faster indications than any other comparable systems available.
Based on even the most conservative assumptions, the cost savings on each start-up cycle between the Waltron dynamic system and the fastest reboiler system is significant. Additional benefits are better energy efficiency and reduced emissions of heat and exhaust.
Revolutionary heatless degassing technology
Achieves 93.5% degassing efficiency
Sample temperature fluctuation does not affect accuracy
No gas emissions or volatile acids
One transmitter for three conductivity values and pH
Alarms for resin exhaustion and low degassing efficiency
Easy to replace cation column
Easy to mount stainless steel panel
Significantly reduced turbine start-up times
PERFORMANCE
Range
0-10µS/cm, 0-100µS/cm
Accuracy
< 0.6% of the measuring range
Reagent Consumption (approximate)
Cation Resin (pre-rinsed) and Soda Lime; replace cartridges every two months
Sensor Classification
Cationic exchange and conductivity sensors
Degassing Efficiency
93.5%
Data Storage
Extract via USB 2.0
Power Supply
AC 110 to 240 V +10 / -15%; 48 to 63 Hz or AC/DC 20 to 30 V; 48 t0 63 Hz
OPERATING CONDITIONS
Sample Temperature Range
32 – 122° F (0 – 50 °C)
Ambient Temperature Range
32 – 140° F (0 – 60 °C)
Inlet Sample Flowrate
.031 – .044 GPM (7-10L/h), 6mm Swagelok
Inlet Sample Pressure
Maximum of 145 psig (10 bar)
Outlet Sample
Atmospheric
SIGNAL OUTPUTS
Analog Outputs
5 x 0/4 – 20 mA for measured signals
Alarms
General Alarm, Low Degassing Efficiency Alarm, Resin Exhausted Alarm
Optional
RS422/RS485
MECHANICAL
Construction
Transmitter – high strength ABS, IP67
Wet section – stainless steel or PVC
Dimensions
29 x 37 x 10″ (613 x 939 x 254mm)
Mounting
Wall mount or Panel mount
Finish
Corrosion resistant