Hotline : (+84) 2206 615 999 / (+84) 981135128 EnglishTiếng Việt

9033X Sodium Analyzer

Added to wishlistRemoved from wishlist 0

Waltron’s 9033X Sodium Analyzer delivers exceptional results in a streamlined low-cost package. An enhanced color touch screen user interface makes the 9033X easy to operate and easy to maintain.

The 9033X Sodium Analyzer can be used in a variety of ultrapure water applications. Common measuring points in a boiler system for online sodium measurement include: make-up water, condensate, boiler feedwater and saturated steam/main steam. The Waltron 9033X Sodium Analyzer comes with true fully automatic calibration and offers many benefits in terms of ease-of-use and increased functionality.

X Module Upgrade.pdf

Large user friendly color touch screen interface


Wide analysis range: 0.1ppb – 10ppm


Multi-stream available


Calibration: automatic 2-point or single point; user may select weekly, bi-monthly, or monthly calibration frequency as well as day and time


Hassle-free maintenance: calibration standards and electrode refill can last up to 3 months


Low sample flow indication (optional)


Quick connect electrodes and probe positioning clamps


Automatic reference electrode electrolyte refill system (standard in US and optional elsewhere)


Grab sample capability


Two 4-20 mA isolated current outputs


Internal data logger set to store readings every 10 minutes for 30 days


External data logger can be set for every 1 minute (optional)


Automatically logs last 10 alarms and results of last 10 calibrations


Reagents: Ammonium Hydroxide (standard) or Di-isopropylamine (optional)


MODBUS and PROFIBUS connections coming soon!

 

PERFORMANCE

Range
0.10ppb – 10ppm


Accuracy
± 5% of reading or ± 0.1ppb to (whichever is greater) within ± 5°C of calibration temperature


Reproducibility
± 5% of reading or ± 0.1ppb (whichever is greater) at constant temperature


Response Time (approximate)
90% of 10 – 1ppb step: less than 3 minutes; 90% of 100 – 1ppb step: 5 minutes


Temperature Compensation
Automatic


pH Compensation
Alkaline vapor buffer:0.88 SG (28% to 30% NH3) ammonia above 0.5ppb sodium, 99% diisopropylamine solution below 0.5ppb sodium


Calibration
Automatic 2-point or single point; user may select weekly, bi-monthly, or monthly calibration frequency as well as day and time


Current Outputs
Two isolated 4-20mA current (analog) outputs


Digital Outputs
Communication interface via RS-232 & RS-485 using MODBUS RTU protocol


Alarms
Low flow alarm and three additional voltage-free contacts, alarm points set from transmitter rated at 2A, 250VAC (non-inductive)


Power
Wide range of input power supply 90VAC – 250VAC


CE Certification (on request)
Meets low voltage and low electromagnetic compatibility directives

SAMPLE DELIVERY OPERATING CONDITIONS

Sample
Temperature: 41 – 131 °F (5 – 55°C); Flow 150 – 400 ml/min


Ambient Temperature
32 – 131°F (0 – 55°C)


Pressure
5 – 30 psig (0.35 – 2.07 bar)


Composition
Sample should be filtered to 60 microns, free of film forming compounds

MECHANICAL

Construction
Transmitter – high strength ABS, IP65 (NEMA 4x)
Wet Section – stainless steel sheet metal, all wetted parts stainless steel or PVC


Dimensions
Height=33.5”(85.1 cm),Width=14.50”(36.83 cm), Depth=11.0”(27.94 cm)


Mounting
Two key-style holes at top: Height=1.38”(3.51 cm), Top Width=0.48”(1.22 cm), Radius=0.47”(1.19 cm) Two bolt notches at bottom: Height=0.88”(2.24 cm),Width=0.48”(1.22 cm), Horizontal=10.25”(26 cm)


Weight
33 lbs. (15 kg)


Wiring
Eight (8) conduit knockouts. Quick connect electrodes.


Piping
Sample Inlet: 1/4″(0.635 cm) OD Swagelok, Drain: 3/8″(0.953 cm) OD tube


Distance
Up to 325 feet (100 meters) on request


Finish
Corrosion resistant

 