9031CX Sodium Analyzer
9065 Luminescent Dissolved Oxygen Analyzer Calibration Kit

9033X Sodium Analyzer

In Stock

Compare

Waltron’s 9033X Sodium Analyzer delivers exceptional results in a streamlined low-cost package. An enhanced color touch screen user interface makes the 9033X easy to operate and easy to maintain.

The 9033X Sodium Analyzer can be used in a variety of ultrapure water applications. Common measuring points in a boiler system for online sodium measurement include: make-up water, condensate, boiler feedwater and saturated steam/main steam. The Waltron 9033X Sodium Analyzer comes with true fully automatic calibration and offers many benefits in terms of ease-of-use and increased functionality.

X Module Upgrade.pdf

Large user friendly color touch screen interface


Wide analysis range: 0.1ppb – 10ppm


Multi-stream available


Calibration: automatic 2-point or single point; user may select weekly, bi-monthly, or monthly calibration frequency as well as day and time


Hassle-free maintenance: calibration standards and electrode refill can last up to 3 months


Low sample flow indication (optional)


Quick connect electrodes and probe positioning clamps


Automatic reference electrode electrolyte refill system (standard in US and optional elsewhere)


Grab sample capability


Two 4-20 mA isolated current outputs


Internal data logger set to store readings every 10 minutes for 30 days


External data logger can be set for every 1 minute (optional)


Automatically logs last 10 alarms and results of last 10 calibrations


Reagents: Ammonium Hydroxide (standard) or Di-isopropylamine (optional)


MODBUS and PROFIBUS connections coming soon!

 

PERFORMANCE

Range
0.10ppb – 10ppm


Accuracy
± 5% of reading or ± 0.1ppb to (whichever is greater) within ± 5°C of calibration temperature


Reproducibility
± 5% of reading or ± 0.1ppb (whichever is greater) at constant temperature


Response Time (approximate)
90% of 10 – 1ppb step: less than 3 minutes; 90% of 100 – 1ppb step: 5 minutes


Temperature Compensation
Automatic


pH Compensation
Alkaline vapor buffer:0.88 SG (28% to 30% NH3) ammonia above 0.5ppb sodium, 99% diisopropylamine solution below 0.5ppb sodium


Calibration
Automatic 2-point or single point; user may select weekly, bi-monthly, or monthly calibration frequency as well as day and time


Current Outputs
Two isolated 4-20mA current (analog) outputs


Digital Outputs
Communication interface via RS-232 & RS-485 using MODBUS RTU protocol


Alarms
Low flow alarm and three additional voltage-free contacts, alarm points set from transmitter rated at 2A, 250VAC (non-inductive)


Power
Wide range of input power supply 90VAC – 250VAC


CE Certification (on request)
Meets low voltage and low electromagnetic compatibility directives

SAMPLE DELIVERY OPERATING CONDITIONS

Sample
Temperature: 41 – 131 °F (5 – 55°C); Flow 150 – 400 ml/min


Ambient Temperature
32 – 131°F (0 – 55°C)


Pressure
5 – 30 psig (0.35 – 2.07 bar)


Composition
Sample should be filtered to 60 microns, free of film forming compounds

MECHANICAL

Construction
Transmitter – high strength ABS, IP65 (NEMA 4x)
Wet Section – stainless steel sheet metal, all wetted parts stainless steel or PVC


Dimensions
Height=33.5”(85.1 cm),Width=14.50”(36.83 cm), Depth=11.0”(27.94 cm)


Mounting
Two key-style holes at top: Height=1.38”(3.51 cm), Top Width=0.48”(1.22 cm), Radius=0.47”(1.19 cm) Two bolt notches at bottom: Height=0.88”(2.24 cm),Width=0.48”(1.22 cm), Horizontal=10.25”(26 cm)


Weight
33 lbs. (15 kg)


Wiring
Eight (8) conduit knockouts. Quick connect electrodes.


Piping
Sample Inlet: 1/4″(0.635 cm) OD Swagelok, Drain: 3/8″(0.953 cm) OD tube


Distance
Up to 325 feet (100 meters) on request


Finish
Corrosion resistant

 

Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “9033X Sodium Analyzer”