3049 Ethylene Glycol Analyzer | ST
9065 Dissolved Oxygen Analyzer
3051 Hardness Analyzer

3049 Ethylene Glycol Analyzer

In Stock

Waltron’s 3049 Ethylene Glycol Analyzeris the most advanced instrumentation for online measurement of ethylene glycol and propylene glycol.

The 3049 stands alone as capable of delivering accurate and precise automatic measurement of ethylene glycol and propylene glycol in water.

Accurate and wide-range analysis


 Multi-stream available


 Fast loop reservoir


 Adjustable cycle and calibration frequency


 Automatic calibration and validation (QA/QC)


 Compact design


 Color touchscreen display


 Grab sample capability


 Internal datalogger


Low reagent level alarm


 Automatic start/stop based on sample flow detection


 Minimal analyzer maintenance


 Automatic operation

 

PERFORMANCE

Sensor Classification
Colormetric with glass flowcell and LED source


Application
Demineralized, boiler, potable, surface and waste water


Power Supply
110-220Vac, 50-60 Hz 80 VA


Humidity
Up to 90% not condensable


Ambient Temperature Range
10-45º C analyzer (50-113º F)


Range
0-15 ppm


Accuracy
+/– 0.1 ppm or +/– 2% of full scale, whichever is greater


Analysis Time
15 min, batch process


Sample Frequency (Cycle Time)
One reading every 20 min, adjustable


Positioning and installation details
Wall mounting or with bench support, panel mounting (optional)


Alarms
2 or 4 configurable alarm relays


Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics


Reagent Consumption (approximate)
4 reagents: Reagent 1 – 2L per month; Reagent 2 – 4L per month; Reagent 3 – 1L per month; Reagent 4 – 4L per month


Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316


CE Certification (on request)
Meets low voltage and low electromagnetic compatibility directives


Sample Conditioning Requirements
Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging


Weight
17 kg (37.5 lbs.)

SAMPLE DELIVERY OPERATING CONDITIONS

Temperature Range
5-55º C (41-131º F)


Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″(6 mm)


Outlet Sample
Atmospheric, waste tubing O.D. 3/8″(9 mm)


PH
3-12

SIGNAL OUTPUTS

Analog Outputs:
4-20mA (galvanic isolator module available as option) or 0-5V


Serial I/O for Signals:
RS232, RS485; MODBUS; PROFIBUS

OPERATIONAL CALIBRATION

Frequency/Intervals
Recommended: daily


Single/Multi-Point
Multi-Point: zero and mid range


Matrix Corrections
Yes, sample blank correction


Manual/Automatic
Both


Reviews

There are no reviews yet.

Be the first to review “3049 Ethylene Glycol Analyzer”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

Your custom content goes here. You can add the content for individual product
İzmit Escort Gebze Escort Sapanca Escort Kocaeli Escort İstanbul Escort Bayan İzmit Escort Gölcük Escort Mersin Escort Altınova Escort Armutlu Escort Çiftlikköy Escort Çınarcık Escort Yalova Escort Yalova Merkez Escort Termal Escort
Back to Top
adapazarı escort serdivan escort sakarya escort