The Waltron 3048 Iron Analyzer provides you with cutting-edge technology for online measurement of dissolved iron in ultrapure water applications.
Online dissolved iron analysis is a growing in popularity as an effective method to monitor corrosion within steam and boiler water systems. Upgrade your manual bench test process to automatic online analysis for accurate and reliable results, greatly enhanced visibility on changes in iron concentrations, and earlier detection of potential problems.
Accurate and wide-range analysis
Multi-stream available
Fast loop reservoir
Adjustable cycle and calibration frequency
Automatic calibration and validation (QA/QC)
Compact design
Color touchscreen display
Grab sample capability
Internal datalogger
Low reagent level alarm
Automatic start/stop based on sample flow detection
Minimal analyzer maintenance
PERFORMANCE
Range
0 – 100ppb, 0 – 5ppm
Accuracy
+/– 2% of full scale
Reproducibility
+/– 2% of reading
Analysis Time
7.5 minutes
Sampling Frequency (Cycle Time)
One reading every 20 minutes (adjustable)
Required Maintenance
Once a month replenish reagents, Quarterly replace tubing
Reagent Consumption (approximate)
1 reagent, 1L per month
Sensor Classification
Colorimetric with glass flowcell and LED source
Application
Boiler water and cooling water
Ambient Temperature Range
10-45ºC analyzer (50-113ºF)
Atmospheric Pressure Range
No Limits
Humidity
Up to 90% not condensable
Unit Dimensions
Height=23.6”(60 cm), Width=15”(38 cm), Depth=8.3”(21 cm)
Positioning and installation details
Wall mounting or with bench support, panel mounting (optional)
Weight
17 kg (37.5 lbs.)
Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics
Alarms
2 or 4 configurable alarm relays
Power Supply
110-220Vac, 50-60 Hz 80 VA
CE Certification (on request)
Meets low voltage and low electromagnetic compatibility directives
SAMPLE DELIVERY OPERATING CONDITIONS
Temperature Range
5-55º C (41-131º F)
Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4”(6 mm)
Outlet Sample
Atmospheric, waste tubing O.D. 3/8”(9 mm)
PH
3-12
Sample Conditioning Requirements
Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging
Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316
SIGNAL OUTPUTS
Analog Outputs
4-20mA (galvanic isolator module available as option) or 0-5V
Serial I/O Options
OPERATIONAL CALIBRATION
Single/Multi Point
Multi-Point: zero and mid range
Matrix Corrections
Yes, sample blank correction
Manual/Automatic
Both