3044 Hydrazine Analyzer
2410 Oil in Water Analyzer

3048 Iron Analyzer

In Stock

Compare

The Waltron 3048 Iron Analyzer provides you with cutting-edge technology for online measurement of dissolved iron in ultrapure water applications.

Online dissolved iron analysis is a growing in popularity as an effective method to monitor corrosion within steam and boiler water systems. Upgrade your manual bench test process to automatic online analysis for accurate and reliable results, greatly enhanced visibility on changes in iron concentrations, and earlier detection of potential problems.

Accurate and wide-range analysis


 Multi-stream available


 Fast loop reservoir


 Adjustable cycle and calibration frequency


 Automatic calibration and validation (QA/QC)


 Compact design


 Color touchscreen display


 Grab sample capability


 Internal datalogger


 Low reagent level alarm


 Automatic start/stop based on sample flow detection


 Minimal analyzer maintenance

 

PERFORMANCE

Range
0 – 100ppb, 0 – 5ppm


Accuracy
+/– 2% of full scale


Reproducibility
+/– 2% of reading


Analysis Time
7.5 minutes


Sampling Frequency (Cycle Time)
One reading every 20 minutes (adjustable)


Required Maintenance
Once a month replenish reagents, Quarterly replace tubing


Reagent Consumption (approximate)
1 reagent, 1L per month


Sensor Classification
Colorimetric with glass flowcell and LED source

Application
Boiler water and cooling water


Ambient Temperature Range
10-45ºC analyzer (50-113ºF)


Atmospheric Pressure Range
No Limits


Humidity
Up to 90% not condensable


Unit Dimensions
Height=23.6”(60 cm), Width=15”(38 cm), Depth=8.3”(21 cm)


Positioning and installation details
Wall mounting or with bench support, panel mounting (optional)


Weight
17 kg (37.5 lbs.)


Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics


Alarms
2 or 4 configurable alarm relays


Power Supply
110-220Vac, 50-60 Hz 80 VA


CE Certification (on request)
Meets low voltage and low electromagnetic compatibility directives

SAMPLE DELIVERY OPERATING CONDITIONS

Temperature Range
5-55º C (41-131º F)


Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4”(6 mm)


Outlet Sample
Atmospheric, waste tubing O.D. 3/8”(9 mm)


PH
3-12


Sample Conditioning Requirements
Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging


Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316

SIGNAL OUTPUTS

Analog Outputs
4-20mA (galvanic isolator module available as option) or 0-5V


Serial I/O Options

OPERATIONAL CALIBRATION

Single/Multi Point
Multi-Point: zero and mid range


Matrix Corrections
Yes, sample blank correction


Manual/Automatic
Both


Đánh giá

Chưa có đánh giá nào.

Hãy là người đầu tiên nhận xét “3048 Iron Analyzer”

Email của bạn sẽ không được hiển thị công khai. Các trường bắt buộc được đánh dấu *

Your custom content goes here. You can add the content for individual product