Waltron’s 3040 series colorimetric analyzers provide exceptional results for online measuring of silica, phosphate and other parameters.
Small size and compact layout make the 3040 series an excellent choice for a variety of applications and environments. Waltron’s 3040 series colorimetric analyzers have been completely redesigned to offer unique and simplified configurations compared to previous models.
Accurate and wide-range analysis
Multi-stream available
Fast loop reservoir
Adjustable cycle and calibration frequency
Automatic calibration and validation (QA/QC)
Compact design
Color touchscreen display
Grab sample capability
Internal datalogger
Low reagent level alarm
No compressed air required
Automatic start/stop based on sample flow detection
Minimal analyzer maintenance
Panel mounting bracket available for Hach 5000 replacement
PERFORMANCE
Range
0 – 100ppb, 0 – 500ppb
Accuracy
+/– 2% of reading
Reproducibility
+/– 2% of reading
Sampling Frequency (Cycle Time)
One reading every 20 mins, adjustable
Required Maintenance
Every 2 weeks replenish reagents; Quarterly replace tubing
Reagent Consumption (approximate)
1 reagent, 4L per month
Sensor Classification
Colorimetric with glass flowcell and LED source
Application
10-45°C analyzer (50-113°F)
Ambient Temperature Range
10-45°C analyzer (50-113°F)
Atmospheric Pressure Range
No Limits
Humidity
Up to 90% not condensable
Unit Dimensions
Height=23.6”(60 cm), Width=15”(38 cm), Depth=8.3”(21 cm)
Positioning and Installation Details
Wall mounting, bench supported, or panel mounting (optional)
Weight
17 kg (37.5 lbs.
Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics
Alarms
2 or 4 configurable alarm relays (Result, loss of sample, fault)
Power Supply (on request)
110-220Vac, 50-60 Hz 80 VA
Certification (on request)
Meets low voltage and low electromagnetic compatibility di
SAMPLE DELIVERY OPERATING CONDITIONS
Temperature Range
5-55º C (41-131º F)
Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″(6mm)
Outlet Sample
Atmospheric, waste tubing O.D. 3/8″(9mm)
PH
3-12
Sample Conditioning Requirements
Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging.
Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316
SIGNAL OUTPUTS
Analog Outputs
4-20mA (galvanic isolator module available as option) or 0-5V)
Serial I/O for Signals
OPERATIONAL CALIBRATION
Single/Multi Point
Multi-Point: zero and mid range
Matrix Corrections
Yes, sample blank correction
Manual/Automatic
Both